J Cardiovasc Thorac Res. 2014;6(3): 147-151.
doi: 10.15171/jcvtr.2014.003
PMID: 25320661
PMCID: PMC4195964
  Abstract View: 2135
  PDF Download: 908

Original Article

Comparison of the Complications between Left Side and Right Side Subclavian Vein Catheter Placement in Patients Undergoing Coronary Artery Bypass Graft Surgery

Masoud Tarbiat 1, Babak Manafi 1, Maryam Davoudi 1*, Ziae Totonchi 2

1 Ekbatan Cardiovascular Surgery Center, Department of Anesthesiology, Hamedan University of Medical Sciences, Hamedan, Iran
2 Department of Anesthesiology, Rajaei Heart Hospital, Iran University of Medical Sciences, Tehran, Iran
*Corresponding Author: Email: Mdavoudi10@yahoo.com

Abstract

Introduction: Percutaneous subclavian vein catheterization is one of the most common invasive procedures performed in cardiac surgery. The aim of this study was to compare left and right subclavian vein catheter placement via the infraclavicular approach in patients who undergo coronary artery bypass graft (CABG) surgery.Methods: This prospective, randomized clinical trial was performed in193 patients. The technique applied for cannulation was infraclavicular approach for both the right and the left sides. Subclavian vein of other side was attempted only when catheterization at initial side was unsuccessful at two attempts. The success and complication rates were compared for the two sides.Results: On193 patients, catheterization attempts were performed. 177 catheterizations (91.7%) were successful during the first attempt, 105 (92.1%) on the right side and 72 (91.1%) on the left side. There was no significant difference between success rate and side of catheterization. Malposition of the catheter tip on the right side (9.6%) was significantly more than the left side (0%) (P= 0.003). The differences in other complications on two sides were statistically insignificant.Conclusion: Compared with the right side, insertion of the cannula on the left side resulted in fewer catheter tip misplacements. Incidence of cannulation failure and other complications were similar on both sides.