Logo-jcvtr
Submitted: 21 Sep 2014
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)

J Cardiovasc Thorac Res. 2014;6(4): 217-221.
doi: 10.15171/jcvtr.2014.015
PMID: 25610552
PMCID: PMC4291599
  Abstract View: 2139
  PDF Download: 828

Original Article

Effect of peripheral edema on cuff-based/ oscillometric blood pressure measurements accuracy

Shamsi Ghaffari 1, Majid Malaki 2*, Afshin Rezaeifar 2, Shahin Abdollahi Fakhim 3

1 Cardiovascular Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
2 Pediatric Health Research Center, Tabriz University of Medical Sciences, Tabriz, Iran
3 Department of Otorhinolaryngology, Tabriz University of Medical Sciences, Tabriz, Iran
*Corresponding Author: Email: madjidmalaki@gmail.com

Abstract

Introduction: Blood pressure( BP )measurement is essential for epidemiological studies and clinical decisions . It seems that tissue characters can effect on BP  resultso and we try to find edema effect on BP measured  by three methods of oscillometric , auscultation and arterial . Method and materials:  Blood pressure of 55 children candidated  for open heart surgery were  measured  and compared with three methods : Arterial as standard and reference  ,oscillometric and auscultatory . Peripheral edema as an tissue character which defined as  higher than +2 as  marked edema and equal or lower than +2  considered as no edema . statistical  method :Data expressed by Mean (95% of confidence interval(CI 95%). Comparison between two group was done by T independent test and ANOVA test for more than two groups. Mann whitney U and paired T test test used for serially comparisons of methods  . P less than 0.05 is significant. Results: 55 children  aged  29.4±3.9 months ,they divided to two groups 10 children with  peripheral edema beyond 2+ and  45 cases without edema. Oscillometric method overestimate systolic BP  the Mean (CI 95%) difference of arterial to oscillomeric was 4.8(8/-1 , p 0.02) in edematous and 4.2(7/1 p 0.004) in non edematous. In diastolic BP oscillometric method underestimate -9(-1.8/-16.5, p0.03) in edematous group and 2.6(-0.7/+5,p 0.2) in non edematous. Conclusion : Oscillometric device standards can not cover all special clinical conditions and age groups .It  underestimate diastolic BP significantly in edematous children,  it was 9.2 mmHg in average as our study.
First Name
Last Name
Email Address
Comments
Security code


Abstract View: 2140

Your browser does not support the canvas element.


PDF Download: 828

Your browser does not support the canvas element.