Logo-jcvtr
Submitted: 31 Jul 2015
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)

J Cardiovasc Thorac Res. 2015;7(3): 87-95.
doi: 10.15171/jcvtr.2015.20
PMID: 26430495
PMCID: PMC4586604
  Abstract View: 1530
  PDF Download: 1075

Original Article

Real Time 3D Echocardiographic Evaluation of Iatrogenic Atrial Septal Defects After Percutaneous Transvenous Mitral Commissurotomy

Sarath Babu Devarakonda 1, Boochi Babu Mannuva 1, Rajasekhar Durgaprasad 1*, Vanajakshamma Velam 1, Vidya Sagar Akula 1, Latheef Kasala 1

1 Department of Cardiology, SVIMS, Tirupati, Andhra Pradesh, India
*Corresponding Author: Email: cardiologysvims@gmail.com

Abstract

Introduction: Percutaneous transvenous mitral commissurotomy (PTMC) is a safe and effective procedure for relief of severe mitral stenosis. PTMC is being done widely and many transseptal procedures requiring large diameter catheters, sheaths are becoming popular. The knowledge of iatrogenic atrial septal defect (iASD) is vital. This study assessed the use of real-time 3D echocardiography (RT3DE) and incidence of iASD in a cohort of patients undergoing transseptal catheterization during PTMC.
Methods:
One hundred ten patients underwent PTMC. The reliability and accuracy of RT3DE for iASD detection was determined, RT3DE was compared with 2D echocardiography (2DE) for iASD occurrence, influencing variables analyzed and followed up for 1 year.
Results:
RT3DE is more reliable and accurate for the study of iASD than 2DE. Color RT3DE detected iASD in 94 (85.5%), with 2DE iASD was detected in 74 (67.3%) (P < .0001). On follow up 85% had iASD post procedure, 56% at 6 months, 19% at 1 year follow up. The mean iASD diameter was 5.41 ± 3.12 mm and area 6.57 ± 3.81 mm2. iASD correlated with patient height, Wilkins score, pre-PTMC LA ‘v’, and post-PTMC LVEDP.
Conclusion:
RT3DE imaging is superior in accuracy to traditional 2DE techniques. All the modes of RT3DE are useful in the assessment of iASD. iASD measured by RT3DE correlates with several patient, procedural and echocardiographic variables.
Keywords: PTMC, RT3DE, iASD
First Name
Last Name
Email Address
Comments
Security code


Abstract View: 1531

Your browser does not support the canvas element.


PDF Download: 1075

Your browser does not support the canvas element.