Logo-jcvtr
Submitted: 06 Jul 2019
Accepted: 25 Aug 2019
ePublished: 06 Oct 2019
EndNote EndNote

(Enw Format - Win & Mac)

BibTeX BibTeX

(Bib Format - Win & Mac)

Bookends Bookends

(Ris Format - Mac only)

EasyBib EasyBib

(Ris Format - Win & Mac)

Medlars Medlars

(Txt Format - Win & Mac)

Mendeley Web Mendeley Web
Mendeley Mendeley

(Ris Format - Win & Mac)

Papers Papers

(Ris Format - Win & Mac)

ProCite ProCite

(Ris Format - Win & Mac)

Reference Manager Reference Manager

(Ris Format - Win only)

Refworks Refworks

(Refworks Format - Win & Mac)

Zotero Zotero

(Ris Format - Firefox Plugin)

J Cardiovasc Thorac Res. 2019;11(4): 309-313.
doi: 10.15171/jcvtr.2019.50
PMID: 31824613
PMCID: PMC6891035
  Abstract View: 1357
  PDF Download: 769

Original Article

Comparison of left ventricular systolic function by 2D speckle-tracking echocardiography between normal pregnant women and pregnant women with preeclampsia

Atoosa Mostafavi 1 ORCID logo, Yaser Tase Zar 1 ORCID logo, Farahnaz Nikdoust 1 ORCID logo, Seyed Abdolhossein Tabatabaei 1* ORCID logo

1 Shariati Hospital, Tehran University of Medical Science, Tehran, Iran
*Corresponding Author: Email: tabatabaeiseyedah@gmail.com

Abstract

Introduction: In light of previous studies reporting the significant effects of preeclampsia on cardiac dimensions, we sought to evaluate changes in the left ventricular (LV) systolic and diastolic functions in patients with preeclampsia with a view to investigating changes in cardiac strain.
Methods: This cross-sectional study evaluated healthy pregnant women and pregnant women suffering from preeclampsia who were referred to our hospital for routine healthcare services. LV strain was measured by 2D speckle-tracking echocardiography.
Results: Compared with the healthy group, echocardiography in the group with preeclampsia showed a significant increase in the LV end-diastolic diameter (47.43 ± 4.94 mm vs 44.84 ± 4.30 mm; P = 0.008), the LV end-systolic diameter (31.16 ± 33.3 mm vs 29.20 ± 3.75 mm; P = 0.008), and the right ventricular diameter (27.93 ± 1.71 mm vs 24.53 ± 23.3; P = 0.001). The mean global longitudinal strain was -18.69 ± 2.8 in the group with preeclampsia and -19.39 ± 3.49 in the healthy group, with the difference not constituting statistical significance (P = 0.164). The mean global circumferential strain in the groups with and without preeclampsia was -20.4 ± 12.4 and -22.68 ± 5.50, respectively, which was significantly lower in the preeclampsia group (P = 0.028).
Conclusion: The development of preeclampsia was associated with an increase in the right and left ventricular diameters, as well as a decrease in the ventricular systolic function, demonstrated by a decline in global circumferential strain.

Please cite this article as: Mostafavi A, Tase Zar Y, Nikdoust F, Abdolhossein Tabatabaei S. Comparison of left ventricular systolic function by 2D speckle-tracking echocardiography between normal pregnant women and pregnant women with preeclampsia. J Cardiovasc Thorac Res 2019;11(4):309-313. doi: 10.15171/jcvtr.2019.50.
First Name
Last Name
Email Address
Comments
Security code


Abstract View: 1358

Your browser does not support the canvas element.


PDF Download: 769

Your browser does not support the canvas element.